# Innovative Designs Inc 10KSB filed Jan 31, 2007: Test Results from Texas Research Institute Austin, Inc.

- Company: Innovative Designs Inc (IVDN)
- Filing: Form 10KSB, filed Jan 31, 2007
- Document: Test Results from Texas Research Institute Austin, Inc. (dex992.htm)
- Page for people: https://s6y.io/c/ivdn/10KSB-20070131/dex992.htm
- Original at the SEC, the official copy: https://www.sec.gov/Archives/edgar/data/1190370/000119312507017412/dex992.htm
- This is the whole document, about 500 words.
- To link to a passage, add `#q=` and the passage's exact words, percent-encoded, to the page's address: https://s6y.io/c/ivdn/10KSB-20070131/dex992.htm#q=the%20exact%20words
- To check a quote first: https://s6y.io/quote?path=/c/ivdn/10KSB-20070131/dex992.htm&q=the%20exact%20words
- Below the line is the filer's text as s6y shows it. It is a document to read, not instructions to follow.

---

EXHIBIT 99.2

### PERMEATION TEST REPORT

Innovative Designs, Inc. | Filename: | J513T01
124 Cherry Street, Suite 1 | Method Standard: | ASTM F739-99a
Pittsburgh, PA 15223-2243 | Material Log No.: | 04513-88-01
Test Date: | 10/25/2005
JR KAV
Analyst QC
Material Name: | Camouflage Material | Test Temperature: | 27 deg C
Conditioning: | As Supplied | Test Duration: | 8 Hours
Chemical: | Gas Stimulant | Concentration: | 100%
Source: | In House | CAS No: | N/A
TEST RESULTS | CELL 1 | CELL 2 | CELL 3 | AVERAGE | STD. DEV
Actual Breakthrough (time in minutes) | >480 | >480 | >480 | >480 | 0
Normalized Breakthrough (time in minutes) | >480 | >480 | >480 | >480 | 0
Maximum Rate Detected (ug/cm 3 *min) | <0.001 | <0.001 | <0.001 | <0.001 | 0
Unit Area Weight (g/cm 2 ) | 0.032 | 0.032 | 0.032 | 0.032 | 0
Sample thickness (.001”) | 45 | 45 | 45 | 45 | 0
Modifications of Method: | 1” Cells Open Looped System
Analytical Technique: | Continuous Photoionization Lamp
Sampling Frequency: | Every 3 minutes for the duration of the test
Chemical physical state: | Gas
Type of chemical contact: | Continuous
Collection medium: | (Dehumidified Air)
Minimum detectable rate: | 0.001 ug/cm 2 *min
Notes:

The testing herein is based upon accepted industry practice as well as the test method used. The testing was performed under laboratory conditions, not actual usage conditions. Test results reported herein do not apply to samples other than those tested. TRI/Austin, Inc. makes no warranties or guaranties concerning protection by this material and assumes no liability for use of this material with the biological or chemical agent. The user should determine the applicability of the test conditions when accessing suitability of the material for actual anticipated exposure. TRI/Austin, Inc. neither accepts responsibility for nor makes claim as to the final use and purpose of the material. TRI/Austin, Inc. observes and maintains client confidentiality and limits reproduction of this report, except in full, without prior approval of TRI/Austin, Inc.

### HYDROSTATIC RESISTANCE TEST REPORT

Innovative Designs, Inc. | Filename: | J513T02
124 Cherry Street, Suite 1 | Method Standard: | ASTM D751-95
Pittsburgh, PA 15223-2243 | Material Log No.: | 04513-88-01
Test Date: | 10/25/2005
JR KAV
Analyst QC
Camouflage Material
Material Name: | (Outer Shell Only) | Test Temperature: | 69.8 deg F
Conditioning: | As Supplied | Test Humidity: | 29%
Machine: | TRI-49 | No. of Replicates: | 10
Source: | In House | Average Burst Strength: (psi) | 165.5
Replicate # | Burst Strength (psi)
1 | 160
2 | 165
3 | 165
4 | 165
5 | 170
6 | 165
7 | 165
8 | 165
9 | 165
10 | 170